Fire Projects Private Limited
Fire Projects Private Limited
Chanakyapuri, Ahmedabad, Gujarat
GST No. 24AADCF1675L1ZI
TrustSEAL Verified
Call 08048116379 57% Response Rate
SEND EMAIL

Gas Suppression System

Take a expert view of Fire Projects Pvt Ltd for design, consultancy, BOQ preparation new implementation of FM200, NOVEC 1230, Inert-clean agent based fire and gas suppression system. Gas Suppression system is most effective way for small to medium size datacentre, UPS room, medical facilities, telecommunication facilities, Electronics & medical equipment, production equipments, libraries, medical record rooms, server rooms, oil pumping stations, engine compartments, switch rooms, engine and machinery spaces, pump rooms and control rooms.

Fire Projects Pvt Ltd also provide AMC–Annual Maintenance Contracts for all types of Gas Suppression System. If you required new installation or AMC of fire suppression system for any of HFC, FK-5-1-12 or Inert based system contact Fire Projects today by writing an Email to Fire Projects Pvt Ltd on: info@fireprojects.co.in

FM200 Fire Suppression System

FM200 Fire Suppression System
  • FM200 Fire Suppression System
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandAnsul
Packaging TypeCarton,Bubble Wrap
Usage/ApplicationIndustrial, Commerical, etc
MaterialCarbon Steel
TypeFire Extinguisher
Featurescost effective,Occupies very less space,lower repair cost
Suppresses ClassA,B and C fires

As a quality focused firm, we are engaged in offering a high quality range of FM200 Fire Suppression System.

Fire Project has expertise in SITC of FM200-Fire Suppression System along with its component. Fire suppression here it called as FM200 gas suppression systems are commonly used in:
  • DATA Centres
  • Comms Rooms
  • Telecommunication facilities
  • UPS Rooms
  • Medical facilities
  • FM200 is waterless, gas based suppression system, which discharge into the risk within 10 seconds depending upon configuration for discharge
  • FM200 is also known as HFC227ea suppresses fire immediately
  • HFC227ea (formed from elements hydrogen, fluorine and carbon) remove the elements of fire triangle (Oxygen, Heat and Fuel)
  • FM200 gas is transparent, colourless and safe for human but may cause frostbite if liquid discharge or escaping vapour contacts the skin
  • Fire Projects has done sevaral designing to installation of FM200 with after sales service
  • Based on infrastructure and requirement we give our expert opinion to prepare BOQ

Complete solution consists following components and accessories required for installation:

FM200 storage components:
  • Cylinder assembly for FM200 chemical agent gas
  • Cylinder brackets

FM200 Distribution components:

  • Discharge nozzles
  • Piping for cylinder and nozzles

Slave components:

  • Pneumatic valve actuators
  • Actuation check valve
  • Vent check
  • Actuation hose
  • Fitting for cylinder (salve arrangement)

Trim components:

  • Pressure gauge
  • Connection fittings
  • Low-pressure supervisory switch
  • Electric valve actuator
  • Manual valve actuator

Supplemental components:

  • Discharge pressure switch
  • Manifold check valve
  • Complete equipment for multi-cylinder configuration
  • Control Panel : It monitor the condition of all connected devices like electric actuator, detectors, warning device, cylinder pressure, manual release and abort stations
  • Optional : VESDA System with control panel

Advantages of an FM200 – Fire suppression system:
  • It react very fast on electrical, flammable liquid fire and suppress fire from infrastructure
  • It save infrastructure from major damage by fire result in lower repair cost
  • Refilling of HFC227ea – FM200 is simple and cost effective
  • Depending upon size of infrastructure, FM200 occupy less space on given infrastructure
  • Compare to other suppression system, FM200 is environment friendly and does not affect stratospheric ozone layer
  • FM200 leaves no residue and safe to use for occupied safe
  • FM200 suppression system is accepted by worldwide including developed and developing nations
Request
Callback
Yes! I am Interested

Fire Suppression System

Fire Suppression System
  • Fire Suppression System
Ask For Price
Product Price :Get Latest Price

Product Details:

Fire Extinguisher TypeCO2 Based
TypeFire Extinguisher
Capacity4Kg
BrandInergen
MaterialMild Steel
Usage/ApplicationFactory

We are indulged in offering the finest quality Fire Suppression System.

Features:

  • Safe for personnel and equipment
  • Leaves no residue behind
  • Most systems are designed to extinguish fires within one minute.
  • Environmentally friendly
  • Actuation by solenoid or manual actuator
  • Three available high-pressure (2900 PSI [200 bar]) cylinder sizes
  • Stored as a gas within the cylinder assembly
  • FM Approved
  • ULC Listed

Other details:
  • With the big push toward "Green", Fire Projects recommend inert gasses which have become a good choice as they are the most green of all of the Clean Agents
  • Inert gasses are defined as using one or more of the gasses Nitrogen, argon, or helium
  • CO2 is also found in one of the inert gas blends. Inert gasses work by removing the oxygen in the hazard to a point where it will not support a fire, but still high enough to support life
  • Design considerations when using inert gasses are pressure venting and volume
  • It is critical to design the system to achieve the correct concentration, and not remove too much oxygen in the room
  • Plus, venting of inert gasses is important as it displaces the air volume in the hazard area
  • Fire Projects can assist in determining which agent is best suited to protect the hazard area (includes detection and control for the system)
  • The air we breathe has approximately 21% of Oxygen
  • Oxygen is the key factor in sustaining a fire and the key factor in keep us alive too
  • By removing the oxygen, we will certainly extinguish a fire, but that comes with obvious problems
  • How do we sustain life at the same time
  • Fires need more than 15% Oxygen to combust
  • Anything below this level of oxygen will not be enough for a fire to sustain combustion
  • Luckily, we only need 12% plus of oxygen to survive and this is where the answer lies
  • To extinguish a fire and sustain life, we need to reduce oxygen from 21% (assuming were at sea level) to below 15%, but not less than 12%
  • This will extinguish a fire and sustain life at the same time


Inert Gas Fire Suppression systems are commonly found with the following blends and names:-

  • Inergen fire suppression - IG541
  • Argon/nitrogen fire suppression - IG55


Inergen fire suppression - IG541:

  • Inergen fire suppression agent is made up of 50% Argon, 42% Nitrogen and 8% Co2
  • The Co2 in this blend helps us absorb oxygen into your blood cells
  • By doing this it decreases the risk of the symptoms described above
  • Co2 is also known to increase our heart beat rate and also induce hyper ventilation
  • This gas clearly suggests an advantage over the other inert gas fire suppression systems, but there is a down side to this
  • If the protected space is filled with toxic bi-products of combustion, the hyper ventilating will introduce more toxins and increase the risk of other side effects


Argon/nitrogen fire suppression - Commonly known as IG55 fire suppression:

  • IG55 fire suppression is a balanced mix of 50% Argon & 50% Nitrogen
  • The fire suppression agent provides good buoyancy, which keeps it in the protected space for longer, thus optimising the suppression period
  • Select Fire Projects for new implementation of Inert fire suppression system is most effective way for small to medium size datacenter, UPS room, medical facilities and telecommunication facilities
  • We support our clients from Designing up to Commissioning up to AMC
Request
Callback
Yes! I am Interested

Honeywell NOVEC 1230 / FK-5-1-12 UL Listed Fire/Gas Suppression System - 42 Bar

Honeywell NOVEC 1230 / FK-5-1-12 UL Listed Fire/Gas Suppression System - 42 Bar
  • Honeywell NOVEC 1230 / FK-5-1-12 UL Listed Fire/Gas Suppression System - 42 Bar
  • Honeywell NOVEC 1230 / FK-5-1-12 UL Listed Fire/Gas Suppression System - 42 Bar
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Fire Suppression TypeCylinder, Pipeline
Pressure25 BAR
Working Temp49.2
ApprovalPESO,IS 7285,UL
Retirement LifeNA
Current24 VDC
Manufactured And Certified ToHONEYWELL,PESO,UL,IS 7285
Burst PressureNA
Model Name/NumberFK-5-1-12
Work LocationDATA CENTER,TELECOM ROOM,SERVER ROOM,ELECTRICAL PANEL ROOM,PROCESS CONTROL ROOM,OIL/GAS
Density Kg M CubeNA
ContentsNA
Body MaterialBrass
Automation GradeAutomatic
Molar MassNA
Ce CertifiedNon Ce Certified
Hose MaterialREINFORCE RUBBER
Storage Pressure360 PSIG
Is It Abrasion ResistanceNA
Usage/ApplicationIndustrial
Wheels MaterialNO
Cylinder MaterialSEAMLESS AND IS 7285
Empty WeightNA
Hose StrapNA
Overall Height MmDEPEND UPON SIZE OF CYLINDER
ConditionNew
Weight316.4
Fire Extinguisher TypeClean Agent Gas Based
Number Of WheelNA
BrandHoneywell
ShapeNA
ResistanceNA
Chemical AgentCF3CF2C(O)CF3)2
Metal UsedYES
FinishingNA
Working Pressure25 and 42 Bar
Installation TypeYes
PowerNA
Diameter Of Cylinder MmDEPEND UPON CYLINDER SIZE
Packaging SizeDEPEND UPON SIZE OF CYLINDER
Filling ToleranceNA
Max Drive Rating HpNA
Control HeadELECTRONIC CONTROL HEAD
DesignNFPA 2001
Pale ShadesNA
Valve MaterialBRASS
VoltageNA
Design/PatternNFPA
Cylinder Height MmDEPEND UPON SIZE OF CYLINDER
ColorColorless Gas
Surface TreatmentNA
Work Temperature Deg CelsiusNA
Mains SupplyNA
Hydraulic TestNA
Types Of MountWALL MOUNT
MaterialBarss
Water ContentNA
Warranty1 YEAR
Thermal ConductivityNA
CoatingNA
CertificationUL
DurationDEPEND UPON DESIGN AND LOCATION
House Reel TubingNA
ThicknessNA
MountedWALL
Extinguishing MediaCF3CF2C(O)CF3)2 / FK-5-1-12 / NOVEC 1230
Duration SecondDEPEND UPON DESIGN AND LOCATION
I Deal InNew Only
FoamNA
Conforming Is SpecnNA
AreaDEPEND UPON ROOM SIZE
GradeNA
Range Of ThrowDEPEND UPON DESIGN
Rated VoltageNA
Discharge Range16.4 to 38.1
Anti Corrosive TreatmentYES
Service PressureNA
PurityNA
Valve Drive Air PressureNA
ExpellantNA
Installation Services RequiredYes
Confirming Is CodeIS 7285
DoseNA
Welding SpeedNA
Jet Length MNA
Fire RatingCLASS A,B,C
TypeCylinder
Hanging Vertically Above RiskNA
Time Of Extinguishing5 TO 10 SECONDS
TemperatureNA
Temperature RangeNA
Neck RingNA
Can HeightNA
Capacity34/80/120/140
Diameter Of CylinderDEPEND UPON CYLINDER SIZE
PerformanceNFPA 2001
Diameter MDEPEND UPON SIZE OF CYLINDER
CabinetNA
Packaging TypeWOODEN BOX
Environment Temp21 'c
Valve HeadcapYES
Cylinder VolumeNA
Stored Gas TypeCLEAN AGENT
Cap MaterialDEPEND UPON CYLINDER SIZE
Tare WeightNA
Density4.7
PropellantNA
Hydraulic Test PressureYES
Number Of CylindersDEPEND UPON ROOM SIZE
DimensionDEPEND UPON CYLINDER SIZE
Suppression SystemAUTOMATIC GAS SUPPRESSION SYSTEM
RangeNA
PortableNon Portable
Size34 Ltr,80 Ltr,120 Ltr,140 Ltr
Test Pressure25 BAR
HeightDEPEND UPON SIZE OF CYLINDER
Discharge Duration5 TO 10 SECONDS
Thickness MmNA
Number Of NozzlesDEPEND UPON ROOM SIZE
Mount TypeWALL MOUNT
Charged WeightDEPEND UPON DESIGN AND CALCULATION
FeaturesClean Agent
Oparating ValveNA
Is It Eco FriendlyEco Friendly
Operation Time In Seconds5 TO 10 SECONDS
Operating PositionNA
Seal Of ApprovalNA
Discharge Time5 to 10 Seconds
Fire ClassData
Filling Density25 BAR
Operating PressureNA
Foam LitreNA
GasFK-5-1-12 / NOVEC 1230
Operating Temperature Limit49.2 Celcius
Sr. NumberNA
Operating Temperature RangeNA
Mounting BracketNA
Minimum Jet LengthNA
Minimum Effective DischargeNA
Dose KgDEPEND UPON SIZE OF CYLINDER
Resistance To CorrosionYES
Types Of Driven GasCF3CF2C(O)CF3)2 - Dodecafiuoro-2-methylpentan-3one
Cylinder Size34 LTR,80 LTR,120 LTR,140 LTR
FrequencyNA
Is It ISI CertifiedNon ISI Certified
HumidityNA
CustomizationNA
Spray Duration5 TO 10 SECOND
Wall ThicknessNA
Rust ProofYES
RatingNA

FK 1230 (FK-5-1-12) Clean agent system also known as NOVEC 1230 are employed to protect critical installations formerly protected by Halon 1301.
  • Data Processing Centers
  • Telephone Switches
  • Process Control Rooms
  • Art and Historical Collections
  • Archive & Museums
  • Marine, Oil & Gas
  • Aerospace, Aviation & Military
FK 1230 (FK-5-1-12) agent compiles with NFPA Standard 2001 : Standard for Clean Agent fire Extinguishing systems, EPA SNAP Program (Significant New Alternate Policy)
Request
Callback


Additional Information:

  • Item Code: H2-120-000
  • Production Capacity: 34 / 80 / 120 / 140 LTR
  • Delivery Time: NORMAL CONDITION 5 TO 7 WEEK
  • Packaging Details: WOODEN PACKAGE
Yes! I am Interested

Fire Suppression System Services

Fire Suppression System Services
  • Fire Suppression System Services
Ask For Price
Product Price :Get Latest Price

Product Details:

Service TypeFire Suppression System Services
Service Duration1-3 Days
Service LocationPAN India

Being one of the trusted organizations in the market, we are indulged in providing a wide range of Fire Suppression System Services.

Fire Projects provides complete Fire Suppression system services, including sales, installation, inspection, recharge, testing, and more. Fire Projects provide the inspection and maintenance schedule to keep your system in compliance, as well as keep accurate inspection and maintenance records that are required by officials. We provide immediate response to fire suppression system discharges, whether accidental or from a fire, to get your system back into service as quickly as possible.


Fire Suppression services include:
  • Testing and cleaning all detectors
  • Verifying shutdown and evacuation circuits
  • Verifying cylinder pressures and weights
  • Checking for changes in hazard integrity
  • Checking input and output circuit supervision
  • Simulating system discharge and testing releasing circuits
  • Visually inspecting agent piping and nozzles
  • Checking hydro test dates for cylinders and discharge hoses

Cylinder/valve assemblies must be handled, installed, inspected and serviced only by qualified and trained personnel in accordance with the instructions contained in this manual, the cylinder nameplate, NFPA-2001, and any other regulations and codes that may apply. Before performing maintenance or refilling procedures refer to the material safety data sheets in the appendix at the back of this manual. A regular program of systematic maintenance must be established for continuous, proper operation of all FM-200, NOVEC 1230 and INERT units, and to avoid violating the warranty. A periodic maintenance schedule must be followed and an inspection log maintained for ready reference.

As a minimum, the log must record:
  • Inspection interval
  • Inspection procedure performed
  • Maintenance performed
Request
Callback
Yes! I am Interested

1230 NOVEC Fire Suppression System

1230 NOVEC Fire Suppression System
  • 1230 NOVEC Fire Suppression System
Ask For Price
Product Price :Get Latest Price

Product Details:

Fire Extinguisher TypeA B C Dry Powder Type
Capacity4Kg
BrandNOVEC
MaterialCarbon Steel
Usage/ApplicationOffice
ColorRed

Fire Projects has expertise in SITC of NOVEC 1230-Fire Suppression System with its component. Fire suppression here it called as NOVEC gas suppression systems are commonly used in:
  • DATA Centres
  • Comms Rooms
  • Telecommunication facilities
  • UPS Rooms
  • Medical facilities

Descriptions:
  • When fire breaks out in server rooms, data-centers, museums and other sensitive environments, sometimes the solution can be as damaging as the fire
  • Novec™ 1230 is a unique fire extinguishing clean agent
  • Among the Clean Agents, it has the lowest atmospheric lifetime of 5 days
  •  It is stored as a liquid, which makes it easier for transport, and also has zero ozone depletion potential
  • As with other clean agents, it is an excellent choice for computer rooms, electrical control rooms, storage areas and any high value area
  • Fire Projects products save people and property from the dangers of fire
  • Our expertise into NOVEC offering and designing
  • Fire Projects is the smart choice when early fire detection and suppression needs are especially demanding
  • Fire Projects will enhance customer focus and partnerships, provide highly efficient service and training, preserve a deep combined expertise in an array of vertical markets, and accelerate our product and technology implementation, to the advantage of everyone who benefits from a world made safer from fire
  • Fire Projects offer Clean Agent Suppression System with Novec 1230 uses a unique approach to deliver the agent to the hazard area
  • By using an external Nitrogen (N2) source to drive the Novec
  • Utilizing super-pressurized Novec fluid propelled by one or two external Nitrogen drivers, Novec system easily achieves bestin-class performance in every category where it matters
  • Nozzles supplied by Fire Projects maximize pressure utilization and are able to cover sub-floors of up to 42.5’ x 42.5’ (12.95m x 12.95m) with a single nozzle
  • Improved agent vaporization allows nozzles to be mounted 18.5’ (5.64m) above the floor deck thereby enabling tall rooms to be protected by a single level of nozzles
  • Fire Projects offer Clean Agent Suppression System with Novec 1230 uses a unique approach to deliver the agent to the hazard area
  • By using an external Nitrogen (N2) source to drive the Novec
  • Utilizing super-pressurized Novec fluid propelled by one or two external Nitrogen drivers, Novec system easily achieves bestin-class performance in every category where it matters
  • Select Fire Projects for new implementation of NOVEC 1230 fire suppression system is most effective way for small to medium size datacenter, UPS room, medical facilities and telecommunication facilities
  • We support our clients from Designing up to Commissioning up to AMC
  • We also provide AMC–Annual Maintenance Contracts for all types of Fire & security Systems

Advantages of an NOVEC 1230 – Fire suppression system:
  • Pipe length from storage to protected area
  • Discharge nozzle coverage area and
  • Discharge nozzle height from floor.
  • Extra Nitrogen Gives You More Coverage While Reducing Installation Costs
  • Centrally-Located Cylinder Banks
  • Increased agent flow rates and distances provide better coverage for larger hazard areas
Request
Callback
Yes! I am Interested
X

Explore More Product



Reach Us
Bhargav Patel (Director)
Fire Projects Private Limited
J-102, Vishwas City 2, R. C. Technical Road, Ghatlodia
Chanakyapuri, Ahmedabad - 380061, Gujarat, India


Call Us


Send E-mailSend SMS