Product Details:
Standby Current | (24VDC) 17 mA Max |
Avg Current | During Testing 500 mA Max |
Alarm Current | (24VDC) 38.5 mA Max |
Fault Current | (24VDC) 8.5 mA Max |
Alignment Mode Current | (24VDC) 28 mA Max |
Current | 450 mA Max at 32 V (per reflector) |
Power Consumption | 7.7 W at 24 V; 15 W at 32 V (per reflector) |
Protection Range | 16 ft to 328 ft (5 m to 100 m) |
Product Details:
Usage/Application | Office Buildings |
Power Source | Electric |
Alarm Current | (24VDC) 8.5 mA Max |
Humidity | 10 to 93% |
Temperature | -30 to 55 Deg C |
Avg. Current | During Testing 500 mA Max |
Fault Current | (24VDC) 4.5 mA Max |
Alignment Mode Current | (24VDC) 20 mA Max |
Power Consumption | 7.7 W at 24 V; 15 W at 32 V (per reflector) |
Protection Range | 16 ft to 328 ft (5 m to 100 m) |
Detector Dimensions | 254 mm H x 191 mm W x 84 mm D |
Reflector Dimensions | 200 mm x 230 mm |
Product Details:
Weight | 8mA |
Brand | Fireray |
Housing | 5 to 100m |
IP Rating | 12 to 36V DC +-10% |
Head Dimension | 134mm H x 131mm L x 134mm W |
Primary Input Power | 14 to 36 VDC |
Standby Current | 5mA to 8.5mA |
Alarm Current | 5mA to 8.5mA |
Reset Time | 5 Seconds maximum |
Start Up Time | 45 sec |
Relative Humidity | 0% to 93% RH non-condensing |
Owing to our immense market knowledge, we are able to offer excellent quality Beam Motorized Reflective Detector.
Fire Projects does SITC - supply, install, test and commission the Fireray 5000, which is motorised reflective type optical beam smoke detector with auto aligning infrared optical beam smoke detector can be installed with up to two detector heads per system, thus saving on installation time and costs. In addition, each system controller houses two pairs of fire and fault relays, one per detector. This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user, both now and in the future.
With its industry leading optics, the Fireray 5000 is ideally suited for the protection of large areas where the use of traditional detection technologies would prove to be too difficult and/or costly to install.
The Fireray 5000 supplied by Fire Projects, combines an infrared transmitter and receiver in the same discrete unit and operates by projecting a well-defined beam to a reflective prism, which returns the beam to the receiver for analysis. Smoke in the beam path causes a drop in power, which, if below a pre-determined level, results in an alarm signal.
Fireray 5000 is quickest and easiest detector, which is getting system operation simplified by number of ground breaking features. A full range of installation acessories are available including the new Adjustment Bracket, which allows a greater degree of flexibility during installation. Once detector head are connected, using esifit First fix system, and integral laser can be activated. This allows the reflective prism to be positioned quickly and with confidence. Once the laser has been used to coarsely align the beam, Auto-align take over and automatically steers the beam into the optimum position. During alignment the system automatically switches to high current mode and drops back to low current mode when in normal operation, however alignment is still possible to in low current mode.
Fireray 5000 motorised reflective type of beam smoke detector supplied by Fire Projects has following features:
• Allows for 2 Detectors per System Controller
• Each Detector configurable from 8m to 100m
• Separate Fire and Fault relays per Detector
• Integral LASER alignment
• Auto-Align Fast Automatic Beam Alignment
• Building Movement and Contamination Compensation
• Low Level System Controller
• Logs the 50 most recent events per detector
• Programmable Sensitivity and Fire Thresholds
• 20mm Cable Gland Knockouts on System Controller
• 2-wire interface from System Controller to Detector
• For detailed specification, please download datasheet.
Product Details:
Brand | Morley |
Usage/Application | Residential Buildings |
Material | Bayblend FR110 Trim,Lexan Lens Cover,Noryl Blackbox |
Operating Temperature Range | -30 to +55 Deg C |
Weight | 1.77kg |
Humidity | 0-95% |
Ip Rating | IP54 |
Operating Voltage Range | 15 to 32VDC |
Typical Standby Current | 2mA @ 24Vdc |
Maximum Alarm Current | 8.5mA |
Maximum Alignment Current | 20mA |
Max Wire Gauge for Terminals | 2.5mm2 |
Colour | White trim,black box |
Reflector | 200 x 230mm |
Model Number | MI-LPB2 |
Product Details:
Operating Temperature Range | -20 to +55 Deg C |
Brand | Fire Ray |
Operating Range | 5 to 120 m |
Operating Voltage Range | 12 to 36V DC +-10% |
Operating Current | 14mA |
Transmitter Current | 8mA |
Power Down Reset Time | >20 seconds |
Fire and Fault Relay | VFCO 2A @ 30 Volts DC resistive |
Optical Wavelength | 850nm |
Product Details:
Weight | 4 kg |
Brand | Fire Ray |
IP Rating | IP50, IP66 |
Dimensions | 210mm W x 260mm H x 88mm D |
Primary Input Power | 11.5 to 28 VDC |
Protection | 100ma Fuse in Control unit |
Standby Current | 8mA @ 24VDC |
Alarm Current | 16.5mA @ 24 VDC |
Relay Contacts | 2A at 30 VDC, resistive |
Reset Time | 5 Seconds maximum |
Start Up Time | 45 Seconds |
Optical Wavelength | 880nm |
Sensitivity | 25%, 35%, 50% |
Temperature Rating | -20 to 55 Deg C |
Operational Range | 10m - 100m |
Field Wiring Size | 18-14 AWG |