Pioneers in the industry, we offer addressable output control module, morley-ias: mi-dcmo, addressable dual input single output control module, morley-ias: mi-d2icmo, addressable mini micro monitor module, morley-ias: mi-mm3i-s2, addressable input monitor module, morley-ias: mi-dmmi, addressable output control module, morley-ias: mi-d240cmo and addressable zone monitor module, morley-ias: mi-dczrm from India.

Addressable Output Control Module, Morley-IAS: MI-DCMO

Addressable Output Control Module, Morley-IAS: MI-DCMO
  • Addressable Output Control Module, Morley-IAS: MI-DCMO
Get Best Quote
Approx. Price: Rs 4,360 / PieceGet Latest Price
Product Brochure

Product Details:

BrandMorley-IAS by Honeywell
ColorWhite
Dimensions23x93x94 mm
Relative Humidity5 to 95%
Weight62g
Ip RatingIP30
Operating Voltage Range15 to 30VDC
Maximum Standby Current200uA at 24VDC
Fault Detection Delay100 to 400ms
Maximum On Resistance0.13 at 15V
Operating Temperature Range-20 to 60 Deg C

Addressable Output Control Module, Morley-IAS: MI-DCMO is used with the ZX series of intelligent conrol panels to provide either a single alarm circuit or Form C relay.

Addressable Output Control Module, Morley-IAS: MI-DCMO can be used to operte dry contacts for door holders, air handling unit shut down or other similar functions. Optionally the module can be used to supervise wiring to the ouput load providing monitoring of the external load voltage or power supply. If the monitored voltage falls below threshold then a fault condition will be indicated.

Features of Output Relay Control Module:
• DIN rail mounting option
• Surface mounting option
• Tri-colour LED status indication
• Built-in Short Circuit Isolators
• Visible Address selector switches
• LED status visible in 2 planes
• Plug in connectors
• Approved to GEA GEI 1-082 and CEA GEI 1-084
Request
Callback


Additional Information:

  • Item Code: MI-DCMO
  • Delivery Time: 4 to 5 Weeks
Yes! I am Interested

Addressable Dual Input Single Output Control Module, Morley-IAS: MI-D2ICMO

Addressable Dual Input Single Output Control Module, Morley-IAS: MI-D2ICMO
  • Addressable Dual Input Single Output Control Module, Morley-IAS: MI-D2ICMO
  • Addressable Dual Input Single Output Control Module, Morley-IAS: MI-D2ICMO
Get Best Quote
Approx. Price: Rs 6,850 / PieceGet Latest Price
Product Brochure

Product Details:

BrandHoneywell
Materialplastic
System ComponentsFire Alarm Control Panel
Usage/ApplicationIndustrial
TypeAddressable
Model Name/NumberMI-D2ICMO
Body MaterialPlastic
ColorWhite
Weight110g
Automation GradeAutomatic
Voltage18v - 32 VDC
Relay OutputsAlarm Relay, Input Relay
FeaturesDual Input and Single Output Control Modules
Alarm Current18 to 32 VDC
Alarm Indication TypeLed
Operating Voltage15 to 30 Vdc
Relative Humidity0 to 95% maximum non-condensing
AuthenticationLPCB and VdS
Normal Loop Voltage18 Vdc to 24 Vdc
Automatic Gas FloodingNo
Wall MountedYes
I Deal InNew Only
Installation ServiceYes
Standby Current340-660uA at 24 Vdc maximum
Relay Contacts Rating2A at 30 Vdc,resistive load
Terminal Wire2.5 mm2 max

Morley-IAS (MI-D2ICMO): Duel Input and Single Output Control Modules requires three addresses per unit of the ninety-nine possible module addresses available on a loop. It responds to regular polling from the control panel indicated by a pulsing LED every successful communication.

The MI-D2ICMO uses a unique mechanical design allowing each module to be mounted either in a wall box (M200E-SMB) or on a DIN rail (using M200E-DIN). Irrespective of the mounting method chosen, the address switch is both visible and accessible for selection. To help engineers in the maintenance and fault finding process, both the LEDs and the address switches can be viewed without having to remove the cover of the mounting box. The LEDs, being multi colour, provide diagnostic information regarding the status of the output. For ease of installation, testing and maintenance, the field wiring terminals are of a plug in design.

The MI-D2ICMO dual input/single output modules are used with the Morley-IAS intelligent fire alarm control panels to provide a dual input circuit from external devices and a single relay control output circuit. Each input is continuously monitored for normal, open circuit and alarm conditions. Any change in the status of the input circuits are communicated to the panel where the appropriate actions may be undertaken. A single pole volt free changeover relay is available for control of external devices or circuits.

Features:
  • Dual inputs
  • Single relay output
  • DIN rail mounting option
  • Surface mounting option
  • Tri-colour LED status indication
  • Built-in short circuit isolators
  • Visible address selector switches
  • LED status visible in 2 planes
  • Plug in connectors
  • Approved to GEA GEI 1-082
  • and CEA GEI 1-084
Request
Callback


Additional Information:

  • Item Code: MI-D2ICMO
  • Delivery Time: 7 to 8 Weeks
Yes! I am Interested

Addressable Mini Micro Monitor Module, Morley-IAS: MI-MM3i-S2

Addressable Mini Micro Monitor Module, Morley-IAS: MI-MM3i-S2
  • Addressable Mini Micro Monitor Module, Morley-IAS: MI-MM3i-S2
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandMorley-IAS
Model Name/NumberMI-MM3E-S2
Humidity10-93%
Display TypeDigital
Operating Current7V
Operating Temperature0-49 C
Operating Voltage15-32V
Weight57g
Height33mm
Length71mm
Width15mm
Operating Voltage Range15 to 32 V
Supervisory Loop Current97 - 114 uA
Standby Current for Commline7 V
Nominal Standby Current110uA
End-of-Line Resistance47 kohm
Operating Temperature Range0-49 Deg C
Operating Humidity Range10-93%

The MI-MM3E-S2 is an addressable input module. It will interface with contact devices such as security contacts, waterflow switches and call points.

It is capable of being connected in Class B wiring configurations.

It provides a two-wire initiating circuit for normally open contact fire alarm and security devices.

In addition to transmitting the supervised state of the monitored device (normal, open or short), the full analog supervision measurement is sent back to the panel.

The compact size allows it to fit inside devices or juntion boxes behind devices. Its size and light weight allows it to be installed without the need to be rigidly mounted. All Morley-IAS products are covered by our extended 3 year warranty.

Features:
  • Compact size
  • Rotary address switches
  • Low standby current
  • Complies with EN54-18
Request
Callback


Additional Information:

  • Item Code: MI-MM3E-S2
  • Delivery Time: 4 to 5 Weeks
Yes! I am Interested

Addressable Input Monitor Module, Morley-IAS: MI-DMMi

Addressable Input Monitor Module, Morley-IAS: MI-DMMi
  • Addressable Input Monitor Module, Morley-IAS: MI-DMMi
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandMorley
Model Name/NumberMI-DMMI
Weight100-110g
Operating Voltage15 to 30 Vdc
Relative Humidity0 to 95% maximum non-condensing
Dimensions93 x 94 x 23 (mm)
Operating Temperature-20 to 60 Deg C
Standby Current310-600 uA at 24 Vdc maximum
Terminal Wire2.5 mm2 maximum

The MI-DMMI and MI-DMM2I use a unique mechanical design allowing each module to be mounted either in a wall box (M200E-SMB) or on a DIN rail (using M200E-DIN). Irrespective of the mounting method chosen, the address switch is both visible and accessible for selection. To help engineers in the maintenance and fault finding process, both the LEDs and the address switches can be viewed without having to remove the cover of the mounting box. The LEDs, being multi colour, provide diagnostic information regarding the status of the output. For ease of installation, testing and maintenance, the field wiring terminals are of a plug in design.

The MI-DMMI and MI-DMM2I monitor modules are used with the Morley-IAS intelligent fire alarm control panels to provide a single or dual input circuit from external devices.

Each input is continuously monitored for normal, open circuit and alarm conditions. Changes to the status of the input circuits are communicated to the panel where the appropriate actions may be undertaken.

The MI-DMMI requires a single address and the MI-DMM2I two addresses of the ninety-nine possible module addresses available on a loop. It responds to regular polling from the control panel indicated by a pulsing LED every successful communication.

Features:
  • Single or dual inputs
  • DIN rail mounting option
  • Surface mounting option
  • Tri-colour LED status indication
  • Built-in short circuit isolators
  • Visible address selector switches
  • LED status visible in 2 planes
  • Plug in connectors
  • Approved to GEA GEI 1-082 and CEA GEI 1-084
Request
Callback
Yes! I am Interested

Addressable Output Control Module, Morley-IAS: MI-D240CMO

Addressable Output Control Module, Morley-IAS: MI-D240CMO
  • Addressable Output Control Module, Morley-IAS: MI-D240CMO
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandMorley-IAS by Honeywell
ColorWhite
MaterialPlastic
Display TypeAnalog
Power Source15 to 30 Vdc
Model Name/NumberMI-D240CMO
TypeAddressable control or relay module
Alarm RangeNA
Sound LevelNA

Addressable Output Control Module, Morley-IAS: MI-D240CMO are used with the Morley-IAS intelligent fire alarm control panels to provide management of 240Vac loads.

The modules are loop powered devices controlling an unsupervised double pole relay output with one normally open and one normally closed contact. The output relay is a bistable device, latching in either the on or the off state on command from the fire alarm control panel.

Each module uses one of the ninety-nine possible module addresses available on a loop. It responds to regular polling from the control panel, indicated by a pulsing LED every successful communication. Each module is supplied with a built-in isolator for protection. However, to increase application flexibility individual isolators may be switched out as required.

• 240Vac mains switching
• DIN rail mounting option
• Surface mounting option
• Bi-colour LED status indication
• Built-in Short Circuit Isolators
• Visible Address selector switches
• Plug in connectors
• Approved to GEA GEI 1-082 and CEA GEI 1-084
Request
Callback


Additional Information:

  • Item Code: MI-D240CMO
  • Delivery Time: 5 to 6 Weeks
Yes! I am Interested

Addressable Zone Monitor Module, Morley-IAS: MI-DCZRM

Addressable Zone Monitor Module, Morley-IAS: MI-DCZRM
  • Addressable Zone Monitor Module, Morley-IAS: MI-DCZRM
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

System ComponentsFire Alarm Control Panel
TypeAddressable
Usage/ApplicationZone monitor module used to used third party conventional detector
Body MaterialPlastic
ColorWhite
BrandMorley-IAS by Honeywell
Humidity5% to 95% relative humidity (non-condensing)
Display TypeAnalog
Model Name/NumberMI-DCZRM

Addressable Zone Monitor Module, Morley-IAS: MI-DCZRM a zone of non-addressable devices to communicate with a Morley-IAS protocol analogue addressable system. As a result existing non-addressable zones can be integrated into a Morley-IAS protocol system.

The module monitors a zone of two-wire non-addressable devices. Each MI-DCZRM uses one of 99 available module addresses on a loop. A fault signal will be transmitted to the panel in case of an open circuit or short circuit on the non-addressable zone wiring or when the external fault input is pulled low (can be used for power supply monitoring). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations).

The non-addressable zone can be powered from the analogue communication loop or from an external power supply. Where the non-addressable zone is powered from an external power supply, the communication loop is fully isolated from the non-addressable zone and from the power supply.

Features of Zone Monitor Module:

• Connection of a zone of non-addressable detectors to an analogue addressable fire system
• Built in isolation allowing system installation in stages without loss of protection
• Monitors open circuit and short circuit faults
• TRI-Colour Status LED
• Zone powered from addressable loop wiring or external 24V PSU
• Remote reset of non-addressable zone
• Compatible with: Most non-addressable detectors IS non-addressable detectors
• Monitoring of external power supply
• External fault input
• CPD approval to EN54-17 and EN54-18, LPCB and VdS
• DIN rail mountable, consistent with all other modules
• Support for an extended power supply range as low as 18Vdc 60mA with an External PSU
Request
Callback


Additional Information:

  • Item Code: MI-DCZRM
  • Delivery Time: 4 to 5 Weeks
Yes! I am Interested

Addressable Output Control Module, Morley-IAS: MI-DCMO-UL

Addressable Output Control Module, Morley-IAS: MI-DCMO-UL
  • Addressable Output Control Module, Morley-IAS: MI-DCMO-UL
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandMorley-IAS by Honeywell
Humidity10% to 93% non-condensing
Display TypeAnalog
Model Name/NumberMI-DCMO-UL
Dimensions Mm4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep
Contact Rating350 A direct poll (CLIP mode) with LED flashing
Input Voltage15 to 32 VDC
Operating Current15 to 32 VDC
Operating Temperature32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC)
Operating Voltage15 to 32 VDC

Addressable Output Control Module, Morley-IAS: MI-D240CMO-UL provides a circuit for Notification appliances like horns, strobes, and more. Addressability allows the HM-DCMO-UL to be activated through panel programming, on a select (zone or area of coverage) basis. The HM-DCMO-UL is used to switch 24 VDC audible/visual power

• The face plate is made of off-white, heat resistant plastic
• Controls include two rotary switches for direct-dial entry of address-setting
• The HM-DCMO-UL is configured for a single Class B Notification Appliance Circuit
• Built-in type identification automatically matches devices to the control panel
• Internal circuitry powered directly by a two-wire SLC loop. The HM-DCMO-UL module requires power (for horns, strobes, etc.)
• Integral green LED blinks each time a communication is received from the control panel and turns on steady red when activated
• High noise immunity (EMF/RFI)
• The HM-DCMO-UL may be used to switch 24-volt NAC power
• Wide viewing angle of LED
• SEMS screws with clamping plates for easy wiring
• Direct-dial entry of address: 61 -99 for models SMX and STX
Request
Callback


Additional Information:

  • Item Code: MI-DCMO-UL
  • Delivery Time: 6 to 7 Weeks
Yes! I am Interested

Addressable Output Control Module, Morley-IAS: MI-D240CMO-UL

Addressable Output Control Module, Morley-IAS: MI-D240CMO-UL
  • Addressable Output Control Module, Morley-IAS: MI-D240CMO-UL
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandMorley-IAS by Honeywell
Humidity10% to 93% non-condensing
Display TypeDigital, Analog
Model Name/NumberMI-D240CMO-UL
Dimensions Mm4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep
Contact RatingLoad Descripton: Resistive,Maximum Voltage: 30 VDC,Current Rating: 3.0 A
Input Voltage15 to 32 VDC
Operating Current15 to 32 VDC
Operating Temperature32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC)
Operating Voltage15 to 32 VDC

Addressable Output Control Module, Morley-IAS: MI-D240CMO-UL provides the system with a dry contact output for activating a variety of auxilary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis.

The HM-D240CMO-UL may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power

Relay Contact Ratings:

•Load Descripton: Resistive
•Application: Non-Coded
•Maximum Voltage: 30 VDC
•Current Rating: 3.0 A

Agency Listings and Approvals:

Listing and approval below apply to the modules specified in this. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
• UL: S35595
Request
Callback


Additional Information:

  • Item Code: MI-D240CMO-UL
  • Delivery Time: 5 to 6 Weeks
Yes! I am Interested

Addressable Input Monitor Module, Morley-IAS: MI-DMMi-UL

Addressable Input Monitor Module, Morley-IAS: MI-DMMi-UL
  • Addressable Input Monitor Module, Morley-IAS: MI-DMMi-UL
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationAddressable input monitor module supervises Class B circuit of dry contact input devices.
Alarm Sensor TypeSupervise Dry contact
Product TypeMonitor Module supervised third party device by dry potencial free contact
ColorGrey
BrandMorley-IAS by Honeywell
Humidity10% to 93% Non condensing
MaterialPlastic
Display TypeAnalog
Model Name/NumberMI-DMMi-UL
Operating Temperature Range32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC)

Addressable Input Monitor Module, Morley-IAS: MI-DMMi-UL supervises Class B circuit of dry contact input devices.

Key Features of Addressable Input Monitor Module, Morley-IAS: MI-DMMi-UL:

• Built-in type identification automatically identifies this device as a monitor module to the control panel
• Powered directly by two-wire SLC loop. No additional power required
• High noise (EMF/RFI) immunity
• SEMS screws with clamping plates for easy wiring
• Direct-dial entry of address: 61-99 for models SMX and STX
• LED flashes during normal operation and steadily illuminates to indicate alarm
Request
Callback


Additional Information:

  • Item Code: MI-DMMi-UL
  • Delivery Time: 5 to 6 Weeks
Yes! I am Interested

Zone Monitor Module, Notifier: FZM-1

Zone Monitor Module, Notifier: FZM-1
  • Zone Monitor Module, Notifier: FZM-1
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandNotifier by Honeywell
Humidity10% to 93% noncondensing
Model Name/NumberFZM-1
Dimensions Mm4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep
Input Voltage15 to 32 VDC
Operating Temperature32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC).
Operating Voltage15 to 32 VDC

Zone Monitor Module, Notifier: FZM-1 used to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application.

Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop).
Request
Callback


Additional Information:

  • Item Code: FZM-1
  • Delivery Time: 5 to 6 Weeks
Yes! I am Interested

Addressable Firephone Control Module, Notifier: FTM-1

Addressable Firephone Control Module, Notifier: FTM-1
  • Addressable Firephone Control Module, Notifier: FTM-1
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandNotifier by Honeywell
Humidity10% to 93% non-condensing
Display TypeAnalog
Model Name/NumberFTM-1
Dimensions Mm4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep.
Input Voltage15 to 32 VDC.
Operating Current7.5 mA group poll
Operating Temperature32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC).
Operating Voltage15 to 32 VDC.

Addressable Firephone Control Module, Notifier: FTM-1 gives NOTIFIER's NFS-640, NFS2-640, NFS-3030, NFS2-3030 control panels the capability to monitor and control a circuit of up to two firefighter phones. The FTM-1 has the ability to differentiate between normal, off-hook, and trouble conditions. This module is used to connect a remote firefighter telephone to a centralized telephone console. A ringing sound is provided at each off-hook handset until it is connected to the console. The user can then connect that offhook phone to the main riser for the voice evac system.

Wiring to individual telephone jacks and handsets is supervised, and status is reported to the panel as NORMAL, TROUBLE, or OFF HOOK. This module has two pairs of output termination points available for fault-tolerant wiring (Style Z), and includes a panel-controlled LED indicator.
Features of Addressable Firephone Control Module, Notifier: FTM-1: 
• Supports two firefighter telephones in either NFPA Style Y or Style Z (Fault Tolerant) telephone circuits.
• Direct-dial entry of address 01– 159 for FlashScan®.
• Built-in type identification automatically identifies itself to the control panel.
• Internal circuitry and relay powered directly by two-wire SLC loop.
• Integral LED “blinks” green each time a communication isreceived from the control panel.
• LED blink may be deselected globally (affects all devices).
• High noise immunity (EMF/RFI).
• Wide viewing angle of LED.
• SEMS screws with clamping plates for wiring ease.
Request
Callback


Additional Information:

  • Item Code: FTM-1
  • Delivery Time: 8 to 9 Weeks
Yes! I am Interested

Dual Monitor Module, Notifier: FDM-1

Dual Monitor Module, Notifier: FDM-1
  • Dual Monitor Module, Notifier: FDM-1
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandNotifer by Honeywell
Humidity10% to 93% (non-condensing).
Display TypeAnalog
Model Name/NumberFDM-1
Dimensions Mm4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep
Input Voltage15 to 32 VDC
Operating Temperature32 Degree to 120 DegreeF (0 Degree to 49 DegreeC).
Operating Voltage15 to 32 VDC

Dual Monitor Module, Notifier: FDM-1 is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems

Th FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address “26”, then it will automatically assign itself to addresses “26” and “27”. The FDM-1(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panelcontrolled LED.
Request
Callback


Additional Information:

  • Item Code: FDM-1
  • Delivery Time: 5 to 6 Weeks
Yes! I am Interested

Monitor Module, Notifier: FMM-1

Monitor Module, Notifier: FMM-1
  • Monitor Module, Notifier: FMM-1
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Brand32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC).
Humidity10% to 93% noncondensing
Display TypeAnalog
Model Name/NumberFMM-1
Dimensions Mm4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep
Input Voltage15 to 32 VDC
Operating Current1 communication every 5 seconds,47k EOL.
Operating Temperature32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC).
Operating Voltage15 to 32 VDC

Monitor Module, Notifier: FMM-1 is a standard-sized module (typically mounts to a
4" [10.16 cm] square box) that supervises either a Style D
(Class A) or Style B (Class B) circuit of dry-contact input
devices.

 Built-in type identification automatically identifies this device as a monitor module to the control panel.
 Powered directly by two-wire SLC loop. No additional ower required.
 High noise (EMF/RFI) immunity.
 SEMS screws with clamping plates for ease of wiring.
 Direct-dial entry of address: 01  159 on FlashScan oops; 01  99 on CLIP loops.
 LED flashes green during normal operation (programmable option) and latches on steady red to indicate alarm.

The FMM-1(A) Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems.
Request
Callback


Additional Information:

  • Item Code: FMM-1
  • Delivery Time: 5 to 6 Weeks
Yes! I am Interested
X

Explore More Product



Reach Us
Bhargav Patel (Director)
Fire Projects Private Limited
J-102, Vishwas City 2, R. C. Technical Road, Ghatlodia
Chanakyapuri, Ahmedabad - 380061, Gujarat, India


Call Us


Send E-mailSend SMS